Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Arq. neuropsiquiatr ; 66(1): 117-119, mar. 2008. ilus
Article in English | LILACS | ID: lil-479670

ABSTRACT

This is a brief review of the literature focused on the articles that formed the basis for the classification of the nerve fibers. Mention is also made to the origin of the nomenclature of the different motoneurons (a, b and g).


Os autores fazem uma breve revisão da literatura com foco nos artigos que deram origem à classificação das fibras nervosas. É também mencionada no texto a origem da nomenclatura dos diferentes neurônios motores (a, b and g).


Subject(s)
History, 20th Century , Humans , Nerve Fibers/classification , Neuroanatomy/history
2.
Rev. bras. eng. biomed ; 22(2): 143-149, ago. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-587452

ABSTRACT

Fibras finas (FF) aferentes primárias mediam a percepção de sensações relacionadas à dor e à temperatura, e as fibras grossas (FG) ao tato. O objetivo deste trabalho é avaliar percepções relacionadas às FF (picada, pontada, agulhada, queimação) e às FG (aperto, pressão, vibração e movimento)evocadas por estimulação elétrica senoidal com 5 Hz e 2 kHz, respectivamente. O dedo indicador da mão esquerda de 150 voluntários, sem doença neurológica conhecida e medicação, foram estimulados nessas frequências com intensidades decorrente igual ao limiar de sensibilidade (LS) e 1,5 vezes LS.O voluntário escolheu das 8 palavras, 3 que mais se aproximavam à sua percepção do estímulo. Outro grupo de 60 voluntários foi utilizado como controle, sendo que as 3 palavras foram escolhidas sem nenhuma estimulação. O valor de “1” foi atribuído à palavra escolhida, e “0” à não selecionada. As sensações foram agrupadas utilizando-se o vizinho mais próximo (single linkage) e a correlação entre variáveis binárias(tetrachloric correlation). Os resultados indicam uma tendência a sensações de fibras grossas sem estimulação, sendo que 5 Hz evoca principalmente as sensações de fibras finas e 2 kHz as de fibras grossas. A exceção foi a sensação de FF queimação, a qual se mostrou inconsistente em ambos os grupos.


Thin fibers mediate the perception related to temperature and painful sensations, and thick fibers the perception related to touch. This work tries to evaluate the perceptions related to thin (prick, pang, twinge and burning) and thick fibers (squeeze, pressure, movement and vibration) evoked by sinusoidal stimulation with 5 Hz and2 kHz, respectively. The left index fingers of 150 volunteers, without known neurological problems or under medication, were stimulatedat these frequencies and at current intensities equal to the sensory threshold and 1.5 times the sensory threshold. The volunteers chose three words out of eight that better represented the sensation felt during the stimulus. Another group of 60 volunteers was used as control, for which the three words were chosen with no stimulation. The value “1” was attributed to each sensation chosen and “0” forthe others. The sensations were clustered using the single linkage nearest neighbor method and the tetrachloric correlation between binary variables. The results showed a tendency to thick fiber sensations with 2 kHz or no stimulation, while 5 Hz evoked thin fiber sensations. The exception was the FF sensation of burning, which did not fit into any group.


Subject(s)
Humans , Electric Stimulation/instrumentation , Nerve Fibers/classification , Nerve Fibers/physiology , Differential Threshold/classification , Differential Threshold/physiology , Sensory Thresholds/classification , Sensory Thresholds/physiology , Peripheral Nerves/physiology , Perception/classification , Sensation
3.
Actas odontol ; 1(1): 15-26, ene.-jun. 2004.
Article in Spanish | LILACS | ID: lil-520831

ABSTRACT

El complejo dentinopulpar cuenta con una inervación muy abundante. Por el foramen apical de cada diente humano pasan de1000 a 2000 fibras nerviosas. De ellas el 75 por ciento son amielínicas –fibras C- y el 25 por ciento mielínicas -la mayoría Aδ y pocas Aβ -. Lasramificaciones de las fibras Aδ penetran de 100 a 200 micrómetros en aproximadamente la mitad de los túbulos dentinarios,inervando la porción más interna de la dentina. Las terminaciones de las fibras nerviosas funcionan como receptores. Existiríantres grupos de receptores intradentarios: nociceptores específicos, receptores polimodales y posiblemente mecanorreceptores.Los dos primeros proveen información de alerta frente al daño tisular y su estimulación produce sensaciones dolorosas. Lasfibras Aδ intradentales median el dolor agudo intenso, pasajero, típico de la sensibilidad dentinaria. Diversos estímulos (térmicos,mecánicos, osmóticos, etc.) provocan flujo de líquido dentro de los túbulos dentinarios y es este flujo el que estimula a lasfibras nerviosas dentinopulpares. La permeabilidad de la dentina expuesta es una de las variables más importantes en la sensibilidaddentinaria. Las fibras intradentales C median el dolor sordo, difuso, mal localizado y prolongado. Hay pocas evidencias deque los estímulos mecánicos puedan causar una sensación diferente a la dolorosa cuando se aplican al complejo dentinopulpar.Existen también algunas fibras nerviosas autonómicas que tendrían función en la regulación del flujo vascular pulpar...


The dental pulp and dentin are very innervated. Between one and two thousand nerve fibers pass through the apical foramen of ahuman tooth. 75 percent of them are amielinic C-fibers and the rest are mielinic fibers, most of them from the Aδ and some from the Aβtypes. The Aδ endings penetrate 100 –200 micrometers in near half the dentin tubules, innervating the inner portion of the dentin.The endings of the nerve fibers act like receptors. There are three types of intradental receptors: specific nociceptors, polimodalreceptors and probably mechanoreceptors. The first two types provide information about threat of tissue damage and theirstimulation leads to painful sensations. Intradental Aδ fibers mediate sharp temporary pain characteristic of dentin sensibility.Many stimuli (thermal, mechanic, osmotic, etc.) produce fluid flow inside the dentinal tubules, and this flow stimulates dentinopulpalnerve fibers. The permeability of the exposed dentin is one of the main variables in dentin sensibility. Intradental C-fibers mediatedull, bad localized, diffuse pain. There is little evidence that the mechanical stimuli produce a sensation different than pain whenapplied to the dentinopulpal complex. There are some intradental autonomic fibers that may play a role in pulpal blood flowregulation...


Subject(s)
Humans , Dentin/innervation , Dental Pulp/innervation , Nerve Fibers/classification , Nerve Fibers/physiology , Toothache/physiopathology , Dentin Sensitivity/physiopathology
4.
Arq. bras. oftalmol ; 64(2): 109-115, mar.-abr. 2001. ilus, tab
Article in Portuguese | LILACS | ID: lil-286031

ABSTRACT

Objetivo: Verificar a correlaçäo e a correspondência topográfica entre a espessura da camada de fibras nervosas da retina, medidas pelo polarímetro de varredura a laser GDXTM Scanning Laser System e o campo visual, medido pelo perímetro automatizado Humphrey ("white-white") em portadores de glaucoma primário de ângulo aberto. Métodos: Foram investigadas as seguintes correlaçöes: 1- Correlaçäo entre a média da sensibilidade dos quadrantes e do ponto de fixaçäo do campo visual, em decibéis, e a média da espessura da camada de fibras nervosas da retina correspondente, em micra, sem classificaçäo dos olhos dos pacientes quanto ao estadio do comprometimento perimétrico. 2- A mesma correlaçäo anterior, porém, com os olhos dos pacientes distribuídos em classes quanto à alteraçäo perimétrica. 3- Correlaçäo entre os índices globais do campo visual e os índices numéricos do analisador de espessura da camada de fibras nervosas da retina. 4- Correlaçäo entre a média dos valores do gráfico "total deviation" do campo visual e o desvio da normalidade da camada de fibras nervosas da regiäo correspondente. 5- Investigou-se a frequência de correspondência topográfica entre os defeitos perimétricos e as alteraçöes da camada de fibras nervosas da retina. Utilizou-se o coeficiente de correlaçäo de Spearman, sendo o nível de rejeiçäo para a hipótese de nulidade fixado num valor menor ou igual a 0,05 (5 por cento). Resultados: Observou-se as seguintes correlaçöes estatisticamente significantes, mas de forma muito pouco intensa: 1- GDX total e Campo visual total; GDX superior e Campo visual nasal inferior; GDX inferior e Campo visual nasal superior; GDX nasal e Campo visual temporal; GDX superior e Campo visual inferior; GDX inferior e Campo visual superior. 2- GDX inferior e Campo visual nasal (medial) superior dos pacientes classificados como graves. 3- Nos olhos classificados como normais: PSD e EM; CPSD e SI.N os olhos classificados como discretos: SF e SN . Nos olhos classificados como moderados: SF e SI. Nos olhos classificados como graves: MD e SN; MD e EM; MD e S; CPSD e EM. 4- DN te TD t; DN se TD ni; DN i e TD ns. 5- Encontramos correspondência positiva (+) em 36 olhos (51,43 por cento dos casos) e correspondência negativa ( -) em 34 olhos ( 48,57 por cento dos casos)...


Subject(s)
Humans , Glaucoma, Open-Angle/diagnosis , Nerve Fibers/classification , Retina/physiopathology , Visual Fields/physiology , Diagnostic Techniques, Ophthalmological , Fixation, Ocular/physiology , Lasers , Statistics, Nonparametric , Visual Field Tests
5.
Rev. bras. oftalmol ; 57(1): 17-22, jan. 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-213022

ABSTRACT

Cento e dez olhos de 55 pacientes portadores de glaucoma crônico simples e normais foram analisados pelo laser scanning polarímetro (GDx) no intuito de se verificar a sensibilidade e especificidade destas medidas na detecçäo de glaucoma. Utilizando-se todos os parâmetros fornecidos pelo aparelho, obteve-se uma sensibilidade de 87,3 por cento e uma especificidade de 91,1 por cento. Em 86,2 por cento dos casos houve correlaçäo entre o hemisfério de maior perda da camada de fibras nervosas com o hemisfério onde se encontrava o maior defeito de campo visual. O parâmetro número foi o que apresentou isoladamente o maior número de acertos


Subject(s)
Nerve Fibers/classification , Sensitivity and Specificity
6.
In. Paeile Jacquier, Carlos; Bilbeny L., Norberto. El dolor: aspectos básicos y clínicos. Santiago de Chile, Mediterráneo, 2 ed; 1997. p.28-59, ilus.
Monography in Spanish | LILACS | ID: lil-284915
SELECTION OF CITATIONS
SEARCH DETAIL